Main Image
BM1478

2P X 2.50 Sqmm RS-485 Communication Armoured FRLSH Cable

Stranded Annealed Tinned Copper Conductor, PE Insulated, Twisted Pair, Overall Aluminium Foil Shielding along with ATC Drain Wire & ATC Wire Braid Shielding, PVC Inner Jacketed, GI Wire Armoured and FRLSH PVC Outer Jacketed RS-485 Communication Armoured FRLSH Cable. ART, UV, RoHS, REACH, 300/500 V, BS EN: 50288-7 & IS: 1554-1

Data Sheet
Suitable Applications toggle
  • Industrial Automation (e.g., PLCs, Modbus Networks)
  • Building Automation (e.g., HVAC Systems, Access Control)
  • Model Railway Control (Digital Command Control - DCC)
  • Digital Audio and Video Transmission (e.g., AES3, CCTV systems)
  • Data Communication in Harsh or Noisy Environments
  • Connecting VFD, Motors, OSDP, HMI, RTU, POS & SCADA Systems etc.
  • Instrumentation and Computer Cable
  • Stage Lighting Control Using DMX512
Special Features toggle
  • Corrosion Resistance & Easy Solder-Ability
  • Multi-Device Support
    (32 devices/bus)
  • Low Dielectric Insulation
  • Excellent EMI/RFI Protection
  • Mechanical Protection
  • Communication Range: Upto 1200
  • Characteristic Impedance: 120Ω
  • High-Speed Data Rate: Upto- 10Mbps
  • Passes IEC:60332-1-2–Flame Rating
General Reference Standards toggle
BS EN: 50288-7, IS: 1554-1
IEC: 60228, IS: 5831, IS: 3975
ASTM D: 2863, ASTM D: 2843, IEC: 60754-1, IEC: 60332-1-2
Construction and Dimensions toggle
Conductor
Material Stranded (Class 2) Annealed Tinned Copper Conductor
Grade Electrolytic
Area of Conductor 2.50 Sqmm
No. of Strands As per Class 2
Diameter of Each Strand [Before Stranding] As per Class 2
Shape of Conductor Stranded and Circular
Insulation
Material PE Compound
Type of Process Extruded
Thickness [Nom.] 1.2 mm
Core Diameter [Nom.] 4.4 mm
No. of Pairs 2 Pair
Cable Formation
Pair 2 Core twisted with an optimal lay length to form a pair
No. of Twists [Min.] 10 Twists per meter in a pair
Laid-up 2 Pair Lay Up in Concentrically to form a Circular Cable
Overall Foil Shielding
Material Aluminium-Mylar Tape
Type Helically
Thickness [Min.] 0.032 mm
Overlap/Coverage [Min.] 25% / 100%
Binder Tape [If required] Polyester tape shall be provided Below and/or Over Shielding
Drain Wire
Material Annealed Tinned Copper (ATC)
Area of Drain Wire 0.50 Sqmm
Place Laid longitudinally, In contact with metallic side of Al-Mylar tape
Overall Braid Shielding
Material Annealed Tinned Copper (ATC)
Type Braiding (Woven)
Coverage [Min.] 65%
Binder Tape [If required] Polyester tape shall be provided Below and/or Over Shielding
Inner Jacket
Material PVC Compound
Type of Process Extruded
Thickness [Min.] 0.3 mm
Armour
Material Galvanised Steel Round Wire
Layer Single Layer
Size of Armour [Nom.] 0.9 ± 0.030 mm
Outer Jacket
Material FRLSH PVC Compound
Type of Process Extruded
Thickness [Min.] 1.4 mm
Overall Cable Diameter 21.8 ± 3.0 mm
Cable Colour Code toggle
Pair Identification 1st Pair - White & Blue
2nd Pair - White & Orange
Inner Jacket Black
Outer Jacket Grey
Packing and Marking toggle
Printing on Cable < AGILON > < 2P X 2.50 SQ MM > < RS-485 COMMUNICATION ARMOURED FRLSH CABLE > < 300/500 V > < ART > < UV > < RoHS > < REACH > < Year >
Sequential Length Marking At every one meter of interval
Standard Packing Length 1000 Meters
Packing Material Packing shall be done in Non-returnable wooden drum
Tolerance on Length ±5% Tolerance
Electrical Characteristics toggle
Voltage Grade 300/500 V
Max. DC Conductor Resistance 7.71 Ω/km at 20°C
Min. Insulation Resistance 1000 MΩ/km at 20°C
Max. Mutual Capacitance [C-C] 54 pf/m at 1 KHz
Max. Mutual Capacitance [C-S] 90 pf/m at 1 KHz
Max. L/R Ratio 60 μH/Ω
High Voltage Test [C-C] 2 kVac rms for 1 Minute
Nom. Velocity of Propagation 66%
Mechanical Characteristics toggle
Max. Conductor Temperature
Continuous Operation 70°C
During Short Circuit 160°C
Bending Radius [Min.]
During Installation 12 x OD; (Where OD is the Overall Diameter of Cable)
Fixed Installation 10 x OD; (Where OD is the Overall Diameter of Cable)
Properties Before Ageing [For Insulation]
Tensile Strength, Min. 10.0 N/mm²
Elongation at Break, Min. 300%
Properties Before Ageing [For Jacket]
Tensile Strength, Min. 12.5 N/mm²
Elongation at Break, Min. 150%
Environmental and Overall Characteristics toggle
Installation
Suitability Indoor / Outdoor
Temperature Range Fixed Installation: -20°C to +70°C
During Installation: +10°C to +50°C
FRLSH Properties
and Tests
Oxygen Index ≥ 30% at 27±2°C; (When tested as per ASTM D: 2863)
Temperature Index ≥ 250°C; (When tested as per ASTM D: 2863)
HCL Gas Emission ≤ 20% [By weight]; (When tested as per IEC: 60754-1)
Smoke Density Rating ≤ 60%; (When tested as per ASTM D: 2843)
Flame Retardant Test IEC: 60332-1-2
Compliance
Anti Rodent & Termite Properties Yes
UV Resistance Yes
RoHS & REACH Compliant Yes
Logo1 Logo2 Logo3 Logo4 Logo5 Logo6 Logo7 Logo8 Logo9
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.