BM1478
2P X 2.50 Sqmm RS-485 Communication Armoured FRLSH Cable
Stranded Annealed Tinned Copper Conductor, PE Insulated, Twisted Pair, Overall Aluminium Foil Shielding along with ATC Drain Wire & ATC Wire Braid Shielding, PVC Inner Jacketed, GI Wire Armoured and FRLSH PVC Outer Jacketed RS-485 Communication Armoured FRLSH Cable. ART, UV, RoHS, REACH, 300/500 V, BS EN: 50288-7 & IS: 1554-1
Suitable Applications
- Industrial Automation (e.g., PLCs, Modbus Networks)
- Building Automation (e.g., HVAC Systems, Access Control)
- Model Railway Control (Digital Command Control - DCC)
- Digital Audio and Video Transmission (e.g., AES3, CCTV systems)
- Data Communication in Harsh or Noisy Environments
- Connecting VFD, Motors, OSDP, HMI, RTU, POS & SCADA Systems etc.
- Instrumentation and Computer Cable
- Stage Lighting Control Using DMX512
Special Features
- Corrosion Resistance & Easy Solder-Ability
- Multi-Device Support
(32 devices/bus)
- Low Dielectric Insulation
- Excellent EMI/RFI Protection
- Mechanical Protection
- Communication Range: Upto 1200
- Characteristic Impedance: 120Ω
- High-Speed Data Rate: Upto- 10Mbps
- Passes IEC:60332-1-2–Flame Rating
General Reference Standards
BS EN: 50288-7, IS: 1554-1
IEC: 60228, IS: 5831, IS: 3975
ASTM D: 2863, ASTM D: 2843, IEC: 60754-1, IEC: 60332-1-2
Construction and Dimensions
Conductor
| Material | Stranded (Class 2) Annealed Tinned Copper Conductor |
| Grade | Electrolytic |
| Area of Conductor | 2.50 Sqmm |
| No. of Strands | As per Class 2 |
| Diameter of Each Strand [Before Stranding] | As per Class 2 |
| Shape of Conductor | Stranded and Circular |
Insulation
| Material | PE Compound |
| Type of Process | Extruded |
| Thickness [Nom.] | 1.2 mm |
| Core Diameter [Nom.] | 4.4 mm |
| No. of Pairs | 2 Pair |
Cable Formation
| Pair | 2 Core twisted with an optimal lay length to form a pair |
| No. of Twists [Min.] | 10 Twists per meter in a pair |
| Laid-up | 2 Pair Lay Up in Concentrically to form a Circular Cable |
Overall Foil Shielding
| Material | Aluminium-Mylar Tape |
| Type | Helically |
| Thickness [Min.] | 0.032 mm |
| Overlap/Coverage [Min.] | 25% / 100% |
| Binder Tape [If required] | Polyester tape shall be provided Below and/or Over Shielding |
Drain Wire
| Material | Annealed Tinned Copper (ATC) |
| Area of Drain Wire | 0.50 Sqmm |
| Place | Laid longitudinally, In contact with metallic side of Al-Mylar tape |
Overall Braid Shielding
| Material | Annealed Tinned Copper (ATC) |
| Type | Braiding (Woven) |
| Coverage [Min.] | 65% |
| Binder Tape [If required] | Polyester tape shall be provided Below and/or Over Shielding |
Inner Jacket
| Material | PVC Compound |
| Type of Process | Extruded |
| Thickness [Min.] | 0.3 mm |
Armour
| Material | Galvanised Steel Round Wire |
| Layer | Single Layer |
| Size of Armour [Nom.] | 0.9 ± 0.030 mm |
Outer Jacket
| Material | FRLSH PVC Compound |
| Type of Process | Extruded |
| Thickness [Min.] | 1.4 mm |
| Overall Cable Diameter | 21.8 ± 3.0 mm |
Cable Colour Code
| Pair Identification |
1st Pair - White & Blue 2nd Pair - White & Orange |
| Inner Jacket | Black |
| Outer Jacket | Grey |
Packing and Marking
| Printing on Cable | < AGILON > < 2P X 2.50 SQ MM > < RS-485 COMMUNICATION ARMOURED FRLSH CABLE > < 300/500 V > < ART > < UV > < RoHS > < REACH > < Year > |
| Sequential Length Marking | At every one meter of interval |
| Standard Packing Length | 1000 Meters |
| Packing Material | Packing shall be done in Non-returnable wooden drum |
| Tolerance on Length | ±5% Tolerance |
Electrical Characteristics
| Voltage Grade | 300/500 V |
| Max. DC Conductor Resistance | 7.71 Ω/km at 20°C |
| Min. Insulation Resistance | 1000 MΩ/km at 20°C |
| Max. Mutual Capacitance [C-C] | 54 pf/m at 1 KHz |
| Max. Mutual Capacitance [C-S] | 90 pf/m at 1 KHz |
| Max. L/R Ratio | 60 μH/Ω |
| High Voltage Test [C-C] | 2 kVac rms for 1 Minute |
| Nom. Velocity of Propagation | 66% |
Mechanical Characteristics
Max. Conductor Temperature
| Continuous Operation | 70°C |
| During Short Circuit | 160°C |
Bending Radius [Min.]
| During Installation | 12 x OD; (Where OD is the Overall Diameter of Cable) |
| Fixed Installation | 10 x OD; (Where OD is the Overall Diameter of Cable) |
Properties Before Ageing [For Insulation]
| Tensile Strength, Min. | 10.0 N/mm² |
| Elongation at Break, Min. | 300% |
Properties Before Ageing [For Jacket]
| Tensile Strength, Min. | 12.5 N/mm² |
| Elongation at Break, Min. | 150% |
Environmental and Overall Characteristics
Installation
| Suitability | Indoor / Outdoor |
| Temperature Range |
Fixed Installation: -20°C to +70°C During Installation: +10°C to +50°C |
FRLSH Properties
and Tests
and Tests
| Oxygen Index | ≥ 30% at 27±2°C; (When tested as per ASTM D: 2863) |
| Temperature Index | ≥ 250°C; (When tested as per ASTM D: 2863) |
| HCL Gas Emission | ≤ 20% [By weight]; (When tested as per IEC: 60754-1) |
| Smoke Density Rating | ≤ 60%; (When tested as per ASTM D: 2843) |
| Flame Retardant Test | IEC: 60332-1-2 |
Compliance
| Anti Rodent & Termite Properties | Yes |
| UV Resistance | Yes |
| RoHS & REACH Compliant | Yes |
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject