• Building Management & Security System Cables
  • Fire Survival Cables
  • Industrial Automation Cables
  • Bus System Cables
  • Instrumentation Cables
  • Rubber Electrical Cables
  • Marine & Offshore Cables
  • High Temperature Cables
  • PUR Cables
  • Signal & Control Cables
  • Single & Multicore Flexible Cables
  • Thermocouple Cables
  • Coaxial Cable

Main Image
BM2012

2C X 2.50 Sqmm Fire Survival Shielded LSZH Cable

Stranded Annealed Bare Copper Conductor, Double Layer of Glass Mica tape, XLPE Insulated, Overall Shielded with Al-Mylar tape in contact with ATC Drain Wire and Overall LSZH Jacketed Fire Survival Shielded Cable. ART, UV, RoHS, REACH, 300/500 V, BS: 7629-1 & BS EN: 50200 PH60

Data Sheet
Suitable Applications toggle
  • Fire Alarm Circuits
  • Emergency Lighting Systems
  • Critical Control and Signaling Circuits
  • Public Address & Voice Evacuation
  • Magnetic Door Hold Open Devices
  • BMS / ELV Circuits
  • Smoke Extraction & Fire Control Systems
  • Fireman’s Intercom & Emergency Communication
  • Escape Route & Staircase Safety Systems
General Reference Standards toggle
BS: 7629-1, BS EN: 50200 PH60
IEC: 60228, BS: 7655 Sec 1.3, BS: 7655 Sec 6.1
ASTM D: 2843, ASTM D: 2863, IEC: 60754-1, IEC: 60332-1
Construction and Dimensions toggle
Conductor
Material Stranded (Class 2) Annealed Bare Copper Conductor
Grade Electrolytic
Area of Conductor 2.50 Sqmm
No. of Strands As per Class 2
Diameter of Each Strand [Before Stranding] As per Class 2
Shape of Conductor Stranded and Circular
Fire Barrier Tape
Material Double layer of Glass Mica Tape
Type of Process Helically
Coverage [Min.] 100%
Thickness [Min.] 0.11 ± 0.015 mm
Insulation
Material XLPE Compound
Type of Process Extruded
Thickness [Nom.] 0.7 mm
No. of Cores 2 Core
Cable Formation
Laid-up 2 Core Lay Up in Concentrically to form a Circular Cable
Overall Shielded
Material Aluminium-Mylar Tape
Type Helically
Thickness [Min.] 0.030 mm
Overlap/Coverage [Min.] 25% / 100%
Binder Tape [If required] Polyester tape shall be provided Below and/or Over Shielding
Drain Wire
Material Annealed Tinned Copper (ATC)
Place Laid longitudinally, In contact with metallic side of Al-Mylar tape
Area of Drain Wire 0.50 Sqmm
Outer Jacket
Material LSZH Compound
Type of Process Extruded
Thickness [Nom.] 1.0 mm
Overall Cable Diameter 11.0 ± 2.0 mm
Cable Colour Code toggle
Core Identification Brown and Blue
Outer Jacket Red
Packing and Marking toggle
Printing on Cable < AGILON > < 2C X 2.50 SQ MM > < FIRE SURVIVAL SHIELDED LSZH CABLE >
< 300/500 V > < BS EN: 50200 PH60 > < ART > < RoHS > < REACH > < Year >
Sequential Length Marking At every one meter of interval
Standard Packing Length 500 meters
Packing Material Packing shall be done in coils
Tolerance on Length ±5% Tolerance
Electrical Characteristics toggle
Voltage Grade 300/500 V
Max. DC Conductor Resistance 7.41 Ω/km at 20°C
Max. AC Conductor Resistance 9.48 Ω/km at 90°C
Max. Mutual Capacitance [C-C] 150 nF/km at 1 KHz
Max. Mutual Capacitance [C-S] 250 nF/km at 1 KHz
Min. Insulation Resistant constant 3.67 MΩ/km at 90°C±2°C
High Voltage Test [C-C] 2 kVac (rms) for 1 minute
Mechanical Characteristics toggle
Maximum Conductor Temperature
Continuous Operation 90°C
During Short Circuit 250°C
Bending Radius [Min.]
During Installation 12 x OD; (Where OD is the Overall Diameter of Cable)
Fixed Installation 10 x OD; (Where OD is the Overall Diameter of Cable)
Properties Before Ageing (For Insulation)
Tensile Strength, Min. 12.5 N/mm²
Elongation at Break, Min. 200%
Properties Before Ageing (For Jacket)
Tensile Strength, Min. 10.0 N/mm²
Elongation at Break, Min. 100%
Environmental and Overall Characteristics toggle
Installation
Suitability Indoor
Temperature Range Fixed Installation: -20 °C to +90 °C
During Installation: +10 °C to +60 °C
Fire Survival Test
Category Standard 60 As per BS EN: 50200 PH60
LSZH Properties
and Tests
Oxygen Index ≥ 35% at 27±2°C; (When tested as per ASTM D: 2863)
Temperature Index ≥ 250°C; (When tested as per ASTM D: 2863)
HCL Gas Emission ≤ 0.3% [By weight]; (When tested as per IEC: 60754-1)
Smoke Density Rating ≤ 10%; (When tested as per ASTM D: 2843)
Flame Retardant Test IEC: 60332-1-2
Compliance
Anti Rodent & Termite Properties Yes
UV Resistance Yes
RoHS & REACH Compliant Yes
Logo1 Logo2 Logo3 Logo4 Logo5 Logo6 Logo7 Logo8 Logo9
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.