BM2032
2C X 2.50 Sqmm Fire Survival LSZH Cable
Stranded Annealed Bare Copper Conductor, Double Layer Glass Mica taped, XLPE Insulated, Cores laid-up concentrically and Overall LSZH Jacketed Fire Survival LSZH Cable. ART, UV, RoHS, REACH, 300/500 V, BS: 7629-1, BS EN: 50200 PH60
General Reference Standards
BS: 7629-1, BS EN: 50200 PH60
IEC: 60228, BS: 7655 Sec 1.3, BS: 7655 Sec 6.1
ASTM D: 2843, ASTM D: 2863, IEC: 60754-1, IEC: 60332-1
Construction and Dimensions
Conductor
| Material | Stranded (Class 2) Annealed Bare Copper Conductor |
| Grade | Electrolytic |
| Area of Conductor | 2.50 Sqmm |
| No. of Strands | As per Class 2 |
| Diameter of Each Strand [Before Stranding] | As per Class 2 |
| Shape of Conductor | Stranded and Circular |
Fire Barrier Tape
| Material | Double layer of Glass Mica Tape |
| Type of Process | Helically |
| Coverage [Min.] | 100% |
| Thickness [Min.] | 0.11 ± 0.015 mm |
Insulation
| Material | XLPE Compound |
| Type of Process | Extruded |
| Thickness [Nom.] | 0.7 mm |
| No. of Cores | 2 Core |
Cable Formation
| Laid-up | 2 Core Lay Up in Concentrically to form a Circular Cable |
Outer Jacket
| Material | LSZH Compound |
| Type of Process | Extruded |
| Thickness [Nom.] | 1.0 mm |
| Overall Cable Diameter | 10.5 ± 2.0 mm |
Cable Colour Coded
| Core Identification | Brown and Blue |
| Outer Jacket | Red |
Packing and Marking
| Printing on Cable | < AGILON > < 2C X 2.50 SQ MM > < FIRE SURVIVAL LSZH CABLE > < 300/500 V > < BS EN: 50200 PH60 > < ART > < RoHS > < REACH > < Year > |
| Sequential Length Marking | At every one meter of interval |
| Standard Packing Length | 500 meters |
| Packing Material | Packing shall be done in coils |
| Tolerance on Length | ±5% Tolerance |
Electrical Characteristics
| Voltage Grade | 300/500 V |
| Max. DC Conductor Resistance | 7.41 Ω/km at 20°C |
| Max. AC Conductor Resistance | 9.48 Ω/km at 20°C |
| Min. Insulation Resistant constant | 3.67 MΩ/km at 90°C±2°C |
| High Voltage Test [C-C] | 2 kVac (rms) for 1 minute |
Mechanical Characteristics
Maximum Conductor Temperature
| Continuous Operation | 90°C |
| During Short Circuit | 250°C |
Bending Radius [Min.]
| During Installation | 12 x OD; (Where OD is the Overall Diameter of Cable) |
| Fixed Installation | 10 x OD; (Where OD is the Overall Diameter of Cable) |
Properties Before Ageing (For Insulation)
| Tensile Strength, Min. | 12.5 N/mm² |
| Elongation at Break, Min. | 200% |
Properties Before Ageing (For Jacket)
| Tensile Strength, Min. | 10.0 N/mm² |
| Elongation at Break, Min. | 100% |
Environmental and Overall Characteristics
Installation
| Suitability | Indoor |
| Temperature Range |
Fixed Installation: -20 °C to +90 °C During Installation: +10 °C to +60 °C |
Fire Survival Test
| Category Standard 60 | EN 50200 PH60 (Annex E) |
LSZH Properties and Tests
| Oxygen Index | ≥ 39% at 27±2°C; (When tested as per ASTM D: 2863) |
| Temperature Index | ≥ 250°C; (When tested as per ASTM D: 2863) |
| HCL Gas Emission | ≤ 0.3% [By weight]; (When tested as per IEC: 60754-1) |
| Smoke Density Rating | ≤ 10%; (When tested as per ASTM D: 2843) |
| Flame Retardant Test | IEC: 60332-1-2 |
Compliance
| Anti Rodent & Termite Properties | Yes |
| UV Resistance | Yes |
| RoHS & REACH Compliant | Yes |
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.