• Building Management & Security System Cables
  • Fire Survival Cables
  • Industrial Automation Cables
  • Bus System Cables
  • Instrumentation Cables
  • Rubber Electrical Cables
  • Marine & Offshore Cables
  • High Temperature Cables
  • PUR Cables
  • Signal & Control Cables
  • Single & Multicore Flexible Cables
  • Thermocouple Cables
  • Coaxial Cable

Main Image
BM1925

2C X 10 Sqmm Fire Survival Armoured LSZH Cable, IS: 17505-1

Stranded Annealed Bare Copper Conductor, Double Layer Glass Mica taped, XLPE Insulated, LSZH Inner Jacket, GI Wire Armoured and Overall HFS-TP 90 (LSZH) Jacketed Fire Survival Armoured Cable. ART, UV, RoHS, REACH, 650/1100 V, BIS Certified & ISI Mark, IS: 17505-1, FWS (950°C for 3H)

Data Sheet
Applications toggle
  • Fire Alarm Systems
  • Public Address Systems
  • Fireman’s Lifts
  • Magnetic Door Hold Open Devices
  • Fire Pumps, Pressurization Systems
  • Emergency Lighting Exit Signage
  • Smoke Ventilation
    (Dampers & Actuators)
  • Fire Fighting Shafts
    (Staircase, Lift, Lift Lobby)
  • Lighting in Fire Command Centers and Security Rooms
  • And other Critical Equipment
Special Features toggle
  • Maintains Electrical Functionality During Fire
  • Resistance to fire at 950 Deg.C for 3 Hours
  • 90% or More Visibility during Fire & Smoke
  • Excellent Flame Retardancy Low Smoke Halogen Free
  • Excellent Crack Resistance
  • Excellent Water Resistant Properties
  • UV Resistant
  • Anti Rodent & Termite Properties
General Reference Standards toggle
IS: 17505-1
IS: 8130, IS: 3975, IS: 3961-6
IS: 10810 (Part 58), IS: 10810 (Part 59), IS: 10810 (Part 61) IS: 10810 (Part 63), IS: 10810 (Part 64)
Construction and Dimensions toggle
Conductor
Material Stranded (Class 2) Annealed Bare Copper Conductor
Grade Electrolytic
Area of Conductor 10 Sqmm
No. of Strands As per Class 2
Diameter of Each Strand [Before Stranding] As per Class 2
Shape of Conductor Stranded and Circular
Fire Barrier Tape
Material Double Layer of Glass Mica Tape
Type Helically
Coverage [Min.] 100%
Thickness [Min.] 0.11 ± 0.015 mm
Insulation
Material XLPE Compound
Type of Process Extruded
Thickness [Nom.] 0.7 mm
No. of Cores 2 Core
Cable Formation
Laid-up 2 Core Lay Up in Concentrically to form a Circular Cable
Inner Jacket
Material LSZH Compound
Type of Process Extruded
Thickness [Nom.] 0.8 mm
Armouring
Material Galvanised Steel Round Wire
Layer Single Layer
Size of Armour [Nom.] 1.4 ± 0.040 mm
Outer Jacket
Material HFS-TP 90 (LSZH) Compound
Type of Process Extruded
Thickness [Nom.] 1.8 mm
Overall Cable Diameter 21.6 ± 2.0 mm
Cable Colour Code toggle
Core Identification Red and Black
Inner Jacket Black
Outer Jacket Red
Packing and Marking toggle
Printing on Cable < AGILON > < 2C X 10 SQ MM > < FIRE SURVIVAL ARMOURED LSZH CABLE >
< 650/1100 V > < 2XWH > < FWS > < IS: 17505-1 > < ART > < UV > < RoHS >
< REACH > < CM/L Number > < ISI Mark > < Year of Mfg. >
Sequential Length Marking At every one meter of interval
Standard Packing Length 1000 meters
Packing Material Packing shall be done in Non-returnable wooden drum
Tolerance on Length ±5% Tolerance
Electrical Characteristics toggle
Voltage Grade 650/1100 V
Max. DC Conductor Resistance 1.83 Ω/km at 20°C
Max. AC Conductor Resistance 2.34 Ω/km at 90°C
Volume Resistivity [Min.] 1 x 10¹⁴ Ohm-cm at 27°C
1 x 10¹² Ohm-cm at 90°C
High Voltage Test [C-C] 3 kVac rms for 5 Minute
Short Circuit Rating of Conductor 1.43 kA for 1 sec
Mechanical Characteristics toggle
Maximum Conductor Temperature
Continuous Operation 90°C
During Short Circuit 250°C
Bending Radius [Min.]
During Installation 12 x OD; (Where OD is the Overall Diameter of Cable)
Fixed Installation 10 x OD; (Where OD is the Overall Diameter of Cable)
Properties Before Ageing [For Insulation]
Tensile Strength, Min. 12.5 N/mm²
Elongation at Break, Min. 200%
Properties Before Ageing [For Jacket]
Tensile Strength, Min. 10 N/mm²
Elongation at Break, Min. 100%
Environmental and Overall Characteristics toggle
Installation
Suitability Indoor / Outdoor
Temperature Range Fixed Installation: -20°C to +90°C
During Installation: +10°C to +80°C
Fire Resistance Test
[Circuit Integrity]
Resistance to Fire Alone [F] 950ºC for 3 h
Resistance to Fire and Water [W] 650ºC for 15 min followed by 5 bursts for water
Resistance to Fire and Mechanical Shock [Z] 950ºC for 15 min along with 03 mechanical impact
A. C. Continuous
Current Rating
Current Rating in Ground 89 Amp at @ 30°C
Current Rating in Duct 75 Amp at @ 30°C
Current Rating in Air 83 Amp at @ 40°C
LSZH Properties
and Tests
Oxygen Index ≥ 35% at 27±2°C; (When tested as per IS: 10810 Part 58)
Temperature Index ≥ 250°C; (When tested as per IS: 10810 Part 64)
HCL Gas Emission ≤ 0.5% (By weight); (When tested as per IS: 10810 Part 59)
Smoke Density ≤ 10%; (When tested as per IS: 10810 Part 63)
Flame Retardant Test IS: 10810 (Part 61)
Compliance
Anti Rodent & Termite Properties Yes
UV Resistance Yes
RoHS & REACH Compliant Yes
Logo1 Logo2 Logo3 Logo4 Logo5 Logo6 Logo7 Logo8 Logo9
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.