2C X 1.50 Sqmm Control BMS Armoured FRLSH Cable
Stranded Annealed Bare Copper Conductor, XLPE Insulated, Cores laid-up concentrically, PVC Inner Jacket, GI Wire Armoured and Overall FRLSH PVC Jacketed Control BMS Armoured FRLSH Cable. 1100 V
General Reference Standards
BS: 5467, IS: 7098-1
IS: 8130, IS: 5831, IS: 3975
ASTM D: 2843, ASTM D: 2863, IEC: 60754-1, IEC: 60332-1-2
Construction and Dimensions
Conductor
| Material | Stranded (Class 2) Annealed Bare Copper Conductor |
| Grade | Electrolytic |
| Area of Conductor | 1.50 Sqmm |
| No. of Strands | As per Class 2 |
| Diameter of Each Strand [Before Stranding] | As per Class 2 |
| Shape of Conductor | Stranded and Circular |
Insulation
| Material | XLPE Compound |
| Type of Process | Extruded |
| Thickness [Min.] | 0.44 mm |
| No. of Cores | 2 Core |
Cable Formation
| Laid-up | 2 Core Lay Up in Concentrically to form a Circular Cable |
Inner Jacket
| Material | PVC Type ST2 Compound |
| Type of Process | Extruded |
| Thickness [Min.] | 0.3 mm |
Armouring
| Material | Galvanized Steel Round Wire |
| Layer | Single Layer |
| Size of Armour [Nom.] | 0.90 ± 0.030 mm |
Outer Jacket
| Material | FRLSH PVC Type ST2 Compound |
| Type of Process | Extruded |
| Thickness [Min.] | 1.24 mm |
| Overall Cable Diameter | 10.2 ± 2.0 mm |
Cable Colour Code
| Core Identification | Red and Black |
| Inner Jacket | Black |
| Outer Jacket | Black |
Packing and Marking
| Printing on Cable | < AGILON > < 2C X 1.50 SQ MM > < CONTROL BMS ARMOURED FRLSH CABLE > < 1100 V > < 2XWY > < Year > |
| Sequential Length Marking | At every one meter of interval |
| Standard Packing Length | 500 meters |
| Packing Material | Packing shall be done in coils |
| Tolerance on Length | ±5% Tolerance |
Electrical Characteristics
| Voltage Grade | 1100 V |
| Max. DC Conductor Resistance | 12.1 Ω/km at 20°C |
| Max. AC Conductor Resistance | 15.49 Ω/km at 90°C |
| Volume Resistivity [Min.] |
1 x 10¹⁴ Ohm-cm at 27°C 1 x 10¹² Ohm-cm at 90°C |
| High Voltage Test [C-C] | 2 kVac rms for 1 Minute |
| Short Circuit Rating of Conductor | 0.215 kA for 1 Sec |
Mechanical Characteristics
Maximum Conductor Temperature
| Continuous Operation | 90°C |
| During Short Circuit | 250°C |
Bending Radius [Min.]
| During Installation | 12 x OD; (Where OD is the Overall Diameter of Cable) |
| Fixed Installation | 10 x OD; (Where OD is the Overall Diameter of Cable) |
Properties Before Ageing [For Insulation]
| Tensile Strength, Min. | 12.5 N/mm² |
| Elongation at Break, Min. | 200% |
Properties Before Ageing [For Jacket]
| Tensile Strength, Min. | 12.5 N/mm² |
| Elongation at Break, Min. | 150% |
Environmental and Overall Characteristics
Installation
| Suitability | Indoor / Outdoor |
| Temperature Range |
Fixed Installation: -20°C to +90°C During Installation: +10°C to +80°C |
FRLSH Properties
and Tests
and Tests
| Oxygen Index | ≥ 29% at 27±2°C; (When tested as per ASTM D: 2863) |
| Temperature Index | ≥ 250°C; (When tested as per ASTM D: 2863) |
| HCL Gas Emission | ≤ 20% [By weight]; (When tested as per IEC: 60754-1) |
| Smoke Density Rating | ≤ 60%; (When tested as per ASTM D: 2843) |
| Flame Retardant Test | IEC: 60332-1-2 |
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject