BM1837
1P X 22 AWG DMX Lighting Control Cable
Stranded Annealed Tinned Copper Conductor, PE Insulated, Overall Shielded with Aluminium Mylar tape in contact with ATC Drain Wire and ATC Wire Braid and Overall PVC Jacketed DMX Lighting Control Cable. ART, RoHS, REACH, 300 V, BS EN: 50288-7
General Reference Standards
BS EN: 50288-7
IEC: 60228, BS EN: 50290-2-23, BS EN: 50290-2-22,
Construction and Dimensions
Conductor
| Material | Stranded (Class 2) Annealed Tinned Copper Conductor |
| Grade | Electrolytic |
| Area of Conductor | 22 AWG |
| No. of Strands | 7 |
| Diameter of Each Strand [Before Stranding] | 30 AWG |
| Shape of Conductor | Stranded and Circular |
Insulation
| Material | Polyethylene (PE) Compound |
| Type of Process | Extruded |
| Thickness [Nom.] | 0.6 mm |
| Core diameter [Nom.] | 1.40 ± 0.05 mm |
| No. of Pairs | 1 Pair |
Cable Formation
| Pair | 2 Core twisted with an optimal lay length to form a pair |
| No. of Twists [Min.] | 10 Twists per meter in a pair |
Overall Foil Shielding
| Material | Aluminium-Mylar Tape |
| Type | Helically |
| Thickness [Min.] | 0.032 mm |
| Overlap/Coverage [Min.] | 25% / 100% |
| Binder Tape [If required] | Polyester tape shall be provided Below and/or Over Shielding |
Drain Wire
| Material | Annealed Tinned Copper (ATC) |
| Area of Drain Wire | 24 AWG |
| Place | Laid longitudinally, in contact with metallic side of AL-Mylar tape |
Overall Braid Shielding
| Material | Annealed Tinned Copper (ATC) |
| Type | Braiding (Woven) |
| Coverage [Min.] | 80% |
| Binder Tape [If required] | Polyester tape shall be provided Below and/or Over Shielding |
Outer Jacket
| Material | PVC Compound |
| Type of Process | Extruded |
| Thickness [Nom.] | 0.80 mm |
| Overall Cable Diameter | 6.0 ± 1.0 mm |
Cable Colour Code
| Pair Identification | White and Red |
| Outer Jacket | Black |
Packing and Marking
| Printing on Cable |
< AGILON > < 1P X 22 AWG > < DMX LIGHTING CONTROL CABLE > < 300 V > < ART > < RoHS > < REACH > < Year > |
| Sequential Length Marking | At every one meter of interval |
| Standard Packing Length | 300/500 meters |
| Packing Material | Packing shall be done in coils |
| Tolerance on Length | ±5% Tolerance |
Electrical Characteristics
| Voltage Grade | 300 V |
| Max. DC Conductor Resistance | 58.0 Ω/km at 20°C |
| Min. Insulation Resistance | 10 MΩ/km at 20°C |
| Max. Mutual Capacitance [C-C] | 65 nF/km at 1 KHz |
| Max. Mutual Capacitance [C-S] | 110 nF/km at 1 KHz |
| Max. L/R Ratio | 25 μH/Ω |
| High Voltage Test [C-C] | 1.0 kVac rms for 1 Minute |
Mechanical Characteristics
Maximum Conductor Temperature
| Continuous Operation | 70°C |
| During Short Circuit | 160°C |
Bending Radius [Min.]
| During Installation | 12 x OD; (Where OD is the Overall Diameter of Cable) |
| Fixed Installation | 10 x OD; (Where OD is the Overall Diameter of Cable) |
Properties Before Ageing [For Insulation]
| Tensile Strength, Min. | 10.0 N/mm² |
| Elongation at Break, Min. | 300% |
Properties Before Ageing [For Jacket]
| Tensile Strength, Min. | 12.5 N/mm² |
| Elongation at Break, Min. | 150% |
Environmental and Overall Characteristics
Installation
| Suitability | Indoor |
| Temperature Range |
Fixed Installation: -15°C to +70°C During Installation: +10°C to +50°C |
Compliance
| Anti Rodent & Termite Properties | Yes |
| RoHS & REACH Compliant | Yes |
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.