• Building Management & Security System Cables
  • Fire Survival Cables
  • Industrial Automation Cables
  • Bus System Cables
  • Instrumentation Cables
  • Rubber Electrical Cables
  • Marine & Offshore Cables
  • High Temperature Cables
  • PUR Cables
  • Signal & Control Cables
  • Single & Multicore Flexible Cables
  • Thermocouple Cables
  • Coaxial Cable

Main Image
BM1421

1P X 0.50 Sqmm RS-485 Communication FRLSH Cable

Stranded Annealed Tinned Copper Conductor, PE Insulated, Overall Alumnium Foil Shielding along with ATC Drain Wire & ATC Wire Braid Shielding and FRLSH PVC Outer Jacketed RS-485 Communication FRLSH Cable. ART, RoHS, REACH, 300/500 V, BS EN: 50288-7

Data Sheet
Suitable Applications toggle
  • Industrial Automation (e.g., PLCs, Modbus Networks)
  • Building Automation (e.g., HVAC Systems, Access Control)
  • Stage lighting Control Using DMX512
  • Data Communication in Harsh or Noisy Environments
  • Digital Audio and Video Transmission (e.g., AES3, CCTV systems)
  • Model Railway Control (Digital Command Control - DCC)
  • Instrumentation and Computer Cable
  • Connecting VFD, Motors, OSDP, HMI, RTU, POS & SCADA Systems etc.
Special Features toggle
  • Corrosion Resistance & Easy Solder-Ability
  • Multi-Device Support
    (32 Devices/Bus)
  • Low Dielectric Insulation
  • Excellent EMI/RFI Protection
  • Communication Range: Upto 1200
  • Characteristic Impedance: 120Ω
  • High-Speed Data Rate: Upto- 10Mbps
  • Passes IEC: 60332-2-24 Flame Rating
General Reference Standards toggle
BS EN: 50288-7
IEC: 60228, IS: 5831
ASTM D: 2843, ASTM D: 2863, IEC: 60754-1, IEC: 60332-1-2
Construction and Dimensions toggle
Conductor
Material Stranded (Class 2) Annealed Tinned Copper Conductor
Grade Electrolytic
Area of Conductor 0.50 Sqmm
No. of Strands As per Class 2
Diameter of Each Strand [Before Stranding] As per Class 2
Shape of Conductor Stranded and Circular
Insulation
Material PE Compound
Type of Process Extruded
Thickness [Nom.] 0.9 mm
Core Diameter [Nom.] 2.7 mm
No. of Pairs 1 Pair
Cable Formation
Pair 2 Core twisted with an optimal lay length to form a pair
Number of twists [Min.] 10 Twists per meter in a pair
Overall Foil Shielding
Material Aluminium Mylar tape
Type Helically
Thickness [Min.] 0.032 mm
Overlap/Coverage [Min.] 25% / 100%
Binder Tape [If required] Polyester tape shall be provided Below and/or Over Shielding
Drain Wire
Material Annealed Tinned Copper (ATC)
Area of Drain Wire 0.50 Sqmm
Place Laid longitudinally, In contact with metallic side of Al-Mylar tape
Overall Braid Shielding
Material Annealed Tinned Copper Wire Braid
Type Braiding (Woven)
Coverage [Min.] 65%
Binder Tape (If required) Polyester tape shall be provided below and/or over shielding
Outer Jacket
Material FRLSH PVC Compound
Type of Process Extruded
Thickness [Nom.] 0.9 mm
Overall Cable Diameter 8.1 ± 1.0 mm
Cable Colour Code toggle
Pair Identification White and Blue
Outer Jacket Grey
Packing and Marking toggle
Printing on Cable < AGILON > < 1P X 0.50 SQ MM > < RS-485 COMMUNICATION FRLSH CABLE >
< 300/500 V > < ART > < RoHS > < REACH > < Year of Mfg. >
Sequential Length Marking At every one meter of interval
Standard Packing Length 500/1000 meters
Packing Material Packing shall be done in Non-returnable wooden drum
Tolerance on Length ±5%
Electrical Characteristics toggle
Voltage Grade 300/500 V
Max. DC Conductor Resistance 36.7 Ω/km at 20°C
Min. Insulation Resistance 1000 MΩ/km at 20°C
Max. Mutual Capacitance [C-C] 40 pf/m at 1 KHz
Max. Mutual Capacitance [C-S] 64 pf/m at 1 KHz
Max. L/R Ratio 25 μH/Ω
High Voltage Test [C-C] 2 kVac (rms) for 1 minute
Nom. Velocity of Propagation 66%
Mechanical Characteristics toggle
Maximum Conductor Temperature
Continuous Operation 70°C
During Short Circuit 160°C
Bending Radius [Min.]
During Installation 12 x OD; (Where OD is the Overall Diameter of Cable)
Fixed Installation 10 x OD; (Where OD is the Overall Diameter of Cable)
Properties Before
Ageing [For Insulation]
Tensile Strength, Min. 10.0 N/mm²
Elongation at Break, Min. 300%
Properties Before
Ageing [For Jacket]
Tensile Strength, Min. 10.0 N/mm²
Elongation at Break, Min. 150%
Environmental and Overall Characteristics toggle
Installation
Suitability Indoor
Temperature Range Fixed Installation: -20°C to +70°C
During Installation: +10°C to +50°C
FRLSH Properties
and Tests
Oxygen Index ≥ 30% at 27±2°C; (When tested as per ASTM D: 2863)
Temperature Index ≥ 250°C; (When tested as per ASTM D: 2863)
HCL Gas Emission ≤ 20% [By weight]; (When tested as per IEC: 60754-1)
Smoke Density Rating ≤ 60%; (When tested as per ASTM D: 2843)
Flame Retardant Test IEC: 60332-1-2
Compliance
Anti Rodent & Termite Properties Yes
RoHS & REACH Compliant Yes
Logo1 Logo2 Logo3 Logo4 Logo5 Logo6 Logo7 Logo8
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.