• Building Management & Security System Cables
  • Fire Survival Cables
  • Industrial Automation Cables
  • Bus System Cables
  • Instrumentation Cables
  • Rubber Electrical Cables
  • Marine & Offshore Cables
  • High Temperature Cables
  • PUR Cables
  • Signal & Control Cables
  • Single & Multicore Flexible Cables
  • Thermocouple Cables
  • Coaxial Cable

Main Image
BM2588

12P X 0.75 Sqmm Shielded BMS Armoured FRLSH Cable

Stranded Annealed Bare Copper Conductor, PVC Insulated, Twisted Pair, Overall Shielded with Aluminium-Mylar tape in contact with ATC Drain Wire, PVC Inner Jacket, GI Wire Armoured and Overall FRLSH PVC Jacketed Shielded BMS Armoured FRLSH Cable. ART, UV, RoHS, REACH, 300/500 V, BS EN: 50288-7 & IS: 1554-1

No Data Sheet Available
Suitable Applications toggle
  • Security Systems
  • Burglar Alarm
  • Intercom / PA-System
  • Cabinet / Panel Wiring
  • Power Limited Circuits
  • Voice Communications
  • Noisy Environment
  • Control Digital Signals
  • Suitable for Upto 500 V Applications
Special Features toggle
  • Anti Rodent & Termite Properties
  • Mechanical Protection
  • RoHS & REACH Compliant
  • UV Resistance
  • Passes IEC: 60332-1, Flame Rating
  • EMI / RFI Protection
Faster Signal Transmission
Faster Signal Transmission
EMI / RFI Protection
EMI / RFI Protection
Minimum Signal Degradation
Minimum Signal Degradation
Mechanical Protection
Mechanical Protection
5 Years Warranty
5 Years Warranty
General Reference Standards toggle
BS EN: 50288-7, IS: 1554-1
IEC: 60228, IS: 5831, IS: 3975
ASTM D: 2843, ASTM D: 2863, IEC: 60754-1, IEC: 60332-1
Construction and Dimensions toggle
Conductor
Material Stranded (Class 2) Annealed Bare Copper Conductor
Grade Electrolytic
Area of Conductor 0.75 Sqmm
No. of Strands As per Class 2
Diameter of Each Strand [Before Stranding] As per Class 2
Shape of Conductor Stranded and Circular
Insulation
Material PVC Compound
Type of Process Extruded
Thickness [Min.] 0.44 mm
No. of Pairs 12 Pair
Cable Formation
Pair 2 Core twisted with an optimal lay length to form a pair
No. of Twists [Min.] 10 Twists per meter in a pair
Laid-up 12 Pair Lay Up in Concentrically to form a Circular Cable
Overall Shielding
Material Aluminium-Mylar Tape
Type of Process Helically
Thickness [Min.] 0.032 mm
Overlap/Coverage [Min.] 25% / 100%
Binder Tape [If required] Polyester tape shall be provided Below and/or Over Shielding
Drain Wire
Material Annealed Tinned Copper (ATC)
Type Laid longitudinally, In contact with metallic side of Al-Mylar tape
Area of Drain Wire 0.50 Sqmm
Inner Jacket
Material PVC Compound
Type of Process Extruded
Thickness [Min.] 0.3 mm
Armouring
Material Galvanised Steel Round Wire
Layer Single Layer
Size of Armour [Nom.] 0.9 ±0.030 mm
Outer Jacket
Material FRLSH PVC Compound
Type of Process Extruded
Thickness [Min.] 1.40 mm
Overall Cable Diameter 20.4 ± 2.0 mm
Cable Colour Coded toggle
Pair Identification White and Blue with Numbering
Inner Jacket Black
Outer Jacket Blue
Packing and Marking toggle
Printing on Cable < AGILON > < 12P X 0.75 SQ MM > < SHIELDED BMS ARMOURED FRLSH CABLE >
< 300/500 V > < ART > < UV > < RoHS > < REACH > < Year >
Sequential Length Marking At every one meter of interval
Standard Packing Length 1000 meters
Packing Material Packing shall be done in Non-returnable wooden drum
Tolerance on Length ±5% Tolerance
Electrical Characteristics toggle
Voltage Grade 300/500 V
Max. DC Conductor Resistance 27.0 Ω/km at 20°C
Min. Insulation Resistance 10 MΩ/km at 20°C
Max. Mutual Capacitance [C-C] 250 nF/km at 1 KHz
Max. Mutual Capacitance [C-S] 450 nF/km at 1 KHz
Max. L/R Ratio 25 μH/Ω
High Voltage Test [C-C] 2 kVac rms for 1 Minute
Mechanical Characteristics toggle
Maximum Conductor Temperature
Continuous Operation 70°C
During Short Circuit 160°C
Bending Radius [Min.]
During Installation 12 x OD; (Where OD is the Overall Diameter of Cable)
Fixed Installation 10 x OD; (Where OD is the Overall Diameter of Cable)
Properties Before Ageing [For Insulation]
Tensile Strength, Min. 12.5 N/mm²
Elongation at Break, Min. 150%
Properties Before Ageing [For Jacket]
Tensile Strength, Min. 12.5 N/mm²
Elongation at Break, Min. 150%
Environmental and Overall Characteristics toggle
Installation
Suitability Indoor / Outdoor
Temperature Range Fixed Installation: -15°C to +70°C
During Installation: +10°C to +60°C
FRLSH Properties
and Tests
Oxygen Index ≥ 30% at 27±2°C; (When tested as per ASTM D: 2863)
Temperature Index ≥ 250°C; (When tested as per ASTM D: 2863)
HCL Gas Emission ≤ 20% [By weight]; (When tested as per IEC: 60754-1)
Smoke Density Rating ≤ 60%; (When tested as per ASTM D: 2843)
Flame Retardant Test IEC: 60332-1-2
Compliance
Anti Rodent & Termite Properties Yes
UV Resistance Yes
RoHS & REACH Compliant Yes
Logo1 Logo2 Logo3 Logo4 Logo5 Logo9 Logo6 Logo7 Logo8
All Rights Reserved © 2025, Agilon Cables India Private Limited
Agilon pursues publishing accurate data,unpredictable variables may result in inadvertent inaccuracies and incompleteness. The details presented herein, though reasonably verified, remain susceptible to unintentional typos or information gaps. Further, product specifications tend to frequently evolve based on ongoing research and feedback. They are subject
to modifications without explicit advance intimations or obligations Also note that Drawings/Images are intended for illustration purposes only and actual product may be vary.